Run 100253 — ATTENTION

Practitioner Cherylee
Condition ATTENTION
Analyzer maglab-analyzer v10
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-17T21:24:14+00:00
App 29
Duration 300.467 s
Run quality COMPLETE

Primary result

Signed field change: +123.8 nT (+0.211%)

Measure Value N / window
Reference field 58.666995 µT 1500 / 0–30 s
Outcome field 58.790765 µT 3000 / 240–300 s
Absolute change 123.8 nT same windows
Angular change 0.088° same windows

Cherylee historical comparison

This run is +149.0 nT relative to Cherylee's 15 historical CONTROL runs (mean -25.2 nT).

Its change is more negative than 6.7% of those controls.

Continuous ambient comparison

Compared with 9 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -118.1 nT.

Summary: ATTENTION; +123.8 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15000 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.0003656 µT/s (0.109681 µT over 0.0–300.0 s, N=15000)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
189–199 s 10 s 188.4 nT 7.46 500
188–198 s 10 s 187.6 nT 7.43 500
187–197 s 10 s 184.9 nT 7.32 500
190–200 s 10 s 175.6 nT 6.95 499
186–196 s 10 s 174.1 nT 6.89 500
191–201 s 10 s 171.8 nT 6.80 501
185–195 s 10 s 168.1 nT 6.66 499
184–194 s 10 s 166.8 nT 6.60 499
178–198 s 20 s 164.6 nT 6.52 999
156–166 s 10 s 163.4 nT 6.47 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.