Run 100252 — ATTENTION

Practitioner unknown
Condition ATTENTION
Analyzer maglab-analyzer v10
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-17T21:25:16+00:00
App 29
Duration 363.556 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +716.4 nT (+1.443%)

Measure Value N / window
Reference field 49.629626 µT 1501 / 0–30 s
Outcome field 50.346022 µT 3000 / 240–300 s
Absolute change 716.4 nT same windows
Angular change 0.205° same windows

Continuous ambient comparison

Compared with 69 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -201.4 nT.

Summary: ATTENTION; +716.4 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=18004 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00306972 µT/s (1.10528 µT over 0.0–360.1 s, N=18004)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
337–347 s 10 s 1079.3 nT 8.90 500
338–348 s 10 s 1078.6 nT 8.89 500
339–349 s 10 s 1072.2 nT 8.84 500
336–346 s 10 s 1068.8 nT 8.81 500
335–345 s 10 s 1065.1 nT 8.78 500
341–351 s 10 s 1063.5 nT 8.77 500
340–350 s 10 s 1063.2 nT 8.77 500
333–343 s 10 s 1062.2 nT 8.76 500
334–344 s 10 s 1058.4 nT 8.73 500
342–352 s 10 s 1057.4 nT 8.72 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.